 +===== 2019 Session 3 =====
 +
 +=== L - Band ===
 +**Jodrell Bank (Lovell)**: 
 +
 +There is no ANTABFS files produced from station for any of the Lovell L band observations, due to a new 
 +source of RFI identified at Jodrell Bank which it appears has had very deleterious effects on all the Lovell L band observations for this session. This new RFI is approximately 30 dB above the noise and 20 Mega Hertz wide, spanning 1472 - 1492 Mega Hertz.
 +
 +The RFI is believed to be for a 4G+ mobile phone service which will bridge the gap between 4G and 5G. It is thought that the signal provides coverage to the Manchester metropolitan area, and this is seen at Pickmere and Darnall too.
 +
 +This signal was first observed in September / October 2019 and they are still devising methods to mitigate its effects. \\
 +
 +===== 2019 Session 2 =====
 +
 +=== L - Band ===
 +**Tianma**: Recorded linear polarization (eg.user experiments - EG100C-D and EH036A-F).\\
 +
 ===== 2019 Session 1 ===== ===== 2019 Session 1 =====
  
Line 17: Line 36:
 **Sardinia**: LL signal in Subband 8 much lower than RR signal.\\ **Sardinia**: LL signal in Subband 8 much lower than RR signal.\\
 **Svetloe**: LCP is broken (at least in the NME).\\ **Svetloe**: LCP is broken (at least in the NME).\\
-**Urumqi**: recorded linear polarization (in the NME and also in the user experiments, eg. EP106E and EP106G).\\ +**Urumqi**: recorded linear polarization (in the NME and also in the user experiments, eg. EP106E, EP106F and EP106G).\\ 
-**Tianma**: recorded linear polarization (in the NME and also in the user experiments, eg. EP106G).+**Tianma**: recorded linear polarization (in the NME and also in the user experiments, eg. EP106F and EP106G).
  
 === C - band === === C - band ===
Line 28: Line 47:
 **KVN**: high invalid data percentage (~7%).\\ **KVN**: high invalid data percentage (~7%).\\
 **Sardinia**: No LL signal in subband 7 (and bad sampler stats there too).\\ **Sardinia**: No LL signal in subband 7 (and bad sampler stats there too).\\
 +
 +=== M - band ===
 +**Torun**: large cross hand amplitude noticed (~30%).\\
 +